We learned this while helping a propane customer in Fallbrook. We were matching a competing bid that specified a Goodman furnace. The Goodman ultra-low NOx specification sheets we reviewed do not list an approved LP conversion kit, and some state the furnaces are for use with natural gas only. The lesson is that not every low-NOx furnace model that people look at for San Diego County work offers a compatible propane conversion kit. That matters in rural and backcountry parts of the county, where homes often heat with propane instead of piped natural gas.

What Rule 69.6 actually requires
The San Diego County Air Pollution Control District's Rule 69.6, "Natural Gas-Fired Fan-Type Central Furnaces," is the air-district rule that sets nitrogen oxides (NOx) limits on those furnaces for use in San Diego County. The current version was adopted and made effective on November 14, 2024. The tighter emission standard took effect on May 14, 2025.
As of that date, no person may manufacture, distribute, sell, offer for sale or install in San Diego County a natural gas-fired, fan-type central furnace with a rated heat input under 175,000 Btu per hour that emits more than 14 nanograms of NOx (calculated as nitrogen dioxide) per joule of heat output. That 14 ng/J limit is what the industry calls ultra-low NOx. The same rule keeps a 40 ng/J limit for natural gas-fired furnaces used in manufactured or mobile homes. The rule's applicability section also includes combination heating and cooling units with a rated cooling capacity under 65,000 Btu per hour.
Two points are easy to mix up, and both are worth getting right:
- Rule 69.6 applies to natural gas-fired furnaces. In its public comments on the 2024 amendments, the District stated that propane-fired furnaces are not subject to Rule 69.6 and do not have to comply with its provisions.
- The air-district rule is not the same thing as a city or county building permit. Replacing a furnace still typically needs a mechanical or building permit and, when the Energy Code requires it, third-party HERS testing. We explain that process in our post on permits and HERS testing.
The District also noted that propane furnaces tend to be natural gas-fired units that are later retrofitted for propane. That is exactly where the kit question comes in. We install ultra-low NOx natural gas furnaces as our standard so the equipment meets code in whatever San Diego County jurisdiction the job is in.
Not every ultra-low NOx model can be converted to propane
Precision Air Inc is a Bryant Factory Authorized Dealer, and the natural gas furnaces we install are ultra-low NOx. Bryant's published product information for its current ultra-low NOx furnaces, including the Evolution 935CA and 830CA and the Legacy 935SA and 830SA, lists those models as natural gas only and not convertible to liquid propane (LP). Bryant's own propane-furnace guide makes the same contrast: some Bryant furnaces, such as the 987M, are listed as convertible to LP with an accessory kit, while the 935CA is listed as natural gas only.
The same check applies to other brands. Goodman's published specifications for its ultra-low NOx furnaces do not list an approved LP conversion kit. Some of those sheets state that the furnaces are for use with natural gas only. Goodman does list LP conversion kits for some of its other furnaces that are not ultra-low NOx. We do not sell every brand, and the only reliable check is the product data for the exact model and size being quoted.
A conversion, when it is allowed, should be done only with the manufacturer's approved kit and procedures, by a qualified technician. Never field-convert a furnace without that approved kit. The orifices, pressure settings and combustion setup are not interchangeable from natural gas to propane.
What this means for homes on propane
Many homes in rural and backcountry San Diego County, including Fallbrook, Ramona, Valley Center and Julian-area neighborhoods, heat with propane because they are not on a natural gas line. If you are replacing a furnace in one of those homes, do not assume that an ultra-low NOx model chosen for the county's 14 ng/J natural-gas standard can be converted to propane. Some can, when the manufacturer publishes an approved kit for that size. Some cannot.
If the job is a propane-fired furnace, Rule 69.6 does not apply to that appliance, per the District. You still want a model that is approved to run on propane, and you still typically need a local permit. If you are looking at an ultra-low NOx furnace and planning to convert it, the kit has to exist for that model first.
Confirm it at the design consultation
The time to catch this is before anyone orders equipment. At Precision Air Inc, a design consultation is paid at the visit and credited toward your job if you go ahead. Tell us that the home uses propane. We will check the model's product data, confirm whether an approved LP conversion kit exists and walk through options that actually fit the house, including a heat pump when that is a better path.
For furnace repair, replacement and installation, see our heating and furnace and furnace replacement pages. Office hours are Monday through Friday, 8 to 5. After hours, our answering service takes your message, and our office follows up the next business day.
Frequently asked questions
Does San Diego County require ultra-low NOx furnaces?
For new natural gas-fired fan-type central furnaces under 175,000 Btu per hour, San Diego County Air Pollution Control District Rule 69.6 requires a limit of 14 nanograms of NOx per joule of heat output, effective May 14, 2025. Furnaces used in manufactured or mobile homes have a 40 ng/J limit. The rule applies to natural gas-fired furnaces. The District has stated that propane-fired furnaces are not subject to Rule 69.6. A city or county building permit is a separate step from this air-district rule.
Can every ultra-low NOx furnace be converted to propane?
No. Some ultra-low NOx models are listed as natural gas only and are not convertible to liquid propane. In the wider market, some manufacturers publish a factory-approved LP conversion kit for certain ultra-low NOx sizes and not for others. Never convert a furnace without the manufacturer's approved kit for that model.
What should I do if my home uses propane?
Tell the contractor at the design consultation, which is paid at the visit and credited toward your job if you go ahead. Have them confirm that the furnace they propose can legally run on propane, including whether an approved conversion kit exists for that model. If a heat pump is a better fit for the house, that can be part of the same conversation.
Need service? Call (760) 858-8000, Monday–Friday 8–5, or send us a message.