What Happens When A Condenser Is Dirty?

Condenser coils that are dirty or contaminated are one of the most common service issues that many homeowners encounter. Furthermore, when a condenser coil becomes dirty or clogged, its ability to reject heat suffers significantly.

Remember that an air conditioner condenser’s primary function is to convert the coolant into liquid, and condensing occurs in the lower two-thirds of the capacitor and is system-dependent. It usually happens when your air conditioning device does not get installed accurately. So whenever you buy a cooling device, it is imperative to call experts for your air conditioning installation in Vista. 

Consequences of a Dirt Condenser

Below are some repercussions of dirty air conditioning condenser coils

Low Heat Transfer

When a condenser becomes dirty or obstructed, the temperature difference from the coolant to the surrounding ambient air is reduced. If an air-cooled compressor can repudiate less heat to the surrounding air due to slagging, heat will begin to accumulate in the capacitor, raising the condensing temperature. 

Once the compressing temperature begins to rise, the difference in temperature between the ambient temperature and the surrounding air (delta T) will become large enough to dismiss heat from the dirty or clogged condenser. Remember that the greater the temperature difference, the greater the heat transfer.

The High Condensation Temperature

The compressor must condense the coolant from a low (evaporating) pressure to a high (condensing) tension when the compressing temperature increases due to a clogged condenser. This additional compression work raises the heat of compression, raising the emission temperature of the compressor. Remember that the compacting temperature is when the refrigerant in the condenser changes phase from vapor to liquid. There is a tense relationship with the saturated steam given this phase transition.

Increased Compression Ratio

Increased compression ratios get induced by either high condensing stresses or low exchanger pressures. There will be increased compression ratios whenever there is high compacting, low exchanger, or both. As a result, more work will be incorporated into the compressor’s compression stroke. More work on the compression stage raises the heat of compression, resulting in a higher discharge temperature for the compressor. 

The compression ratio is calculated by dividing the absolute pressure drop by the ultimate suction pressure. A compression ratio of 7:1 merely means that the pressure drop is seven times the amplitude of the pressure gradient. Again, a compression ratio of 10:1 tells the engineer that the ultimate or true discharge pressure is ten times that of the absolute suction pressure

Volume Effectiveness

When using piston-type compressed air, an increased compression ratio reduces volumetric efficiency. Volume effectiveness is calculated as the proportion of the specific refrigeration cycle pumped by the cylinder to the increase in various compressed air pistons. 

It is expressed in a percentage ranging from 0 to 100 percent. Aimed at maximizing the cylinder volume of the piston, it is filled with new coolant from the suction line rather than re-expanded clearance volume gasses.